L88 Amber

Table of Contents

Flash Pattern

Introduction

The flash pattern setting controls the flash pattern. There are five versions of flash pattern: Double, Triple, Steady burn 1, Steady burn 2 and Indicator.

  • Double and Triple are built-in flash patterns and no control system is needed.

  • With Steady burn 1 and Steady burn 2 an external flasher or control system is used to control the flash pattern.

  • With Indicator the lamp is controlled by the direction indicator system.

The factory setting of flash pattern is Double.

When in configuration mode, the number of blank flashes (lamp off) in the flash sequence show the current flash pattern setting, see table.

Blank flashes per

flash sequence

Flash pattern

Flash control

1

Double

Built-in

2

Triple

Built-in

3

Steady burn 1

External

4

Steady burn 2

External

5

Indicator

Direction indicator system

Setting the Flash Pattern

WARNING

Risk of eye damage. Do not look into the light beam at close range.

WARNING

Hot surfaces. Do not touch the cooling flanges when the lamp is on.

  1. If already in configuration mode, go to step 6.

  1. If the lamp is connected to the power supply, disconnect it.

  2. Connect the red wire to 10-30 V DC via a 5 A fuse.

    Red_to_battery_via_fuse_L88.svg
  3. Connect the black wire to ground.

    Black_to_ground_L88.svg
  4. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec.

    White_to_ground_within_1-6sec_L88.svg

    The lamp enters configuration mode and a flash sequence indicating the current settings starts.

    Note

    If this step is performed incorrectly, you must restart from step 2.

  1. Count the number of blank flashes (lamp off) per flash sequence to find out the current flash pattern setting.

  2. Temporarily connect the white wire to ground to change to the next version of flash pattern. Each time the white wire is temporarily connected to ground the next version of flash pattern is selected.

    White_to_ground_alone.svg
  3. To change the sync mode setting, see Sync Mode. To reset to factory settings, see Factory Reset.

  4. Disconnect the power supply to save the selected settings and exit configuration mode.