Table of Contents

Factory Reset

Introduction

The settings can be changed back to the factory settings. 

The factory settings are like the Preset settings.

Reset to Factory Settings

WARNING

Risk of eye damage. Do not look into the light beam at close range.

Note

All current settings, that is flash pattern setting and sync mode setting, are reset to the default settings.

  1. If already in configuration mode, go to step 6.

  1. If the lamp is connected to the power supply, disconnect it.

  2. Connect the red wire to 10-30 V DC via a 5 A fuse.

    L56_2C_connections_mounting_red.svg
  3. Connect the black wire to ground.

    Lamp_56_2c_connections_mounting_black.svg
  4. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec.

    White_to_ground_within_1-6sec_L52-2C.svg

    The lamp enters configuration mode and a flash sequence indicating the current settings starts.

    Note

    If this step is performed incorrectly, you must restart from step 2.

  1. Connect the YELLOW wire to 10-30 V DC and let it stay connected for at least 2 seconds.

    L56-2C_reset_to_factory_settings_1.svg
  2. The reset is confirmed with a bright flash light for 2-3 seconds.

    L56-2C_reset_to_factory_settings_2.svg