Table of Contents

Flash Pattern

Introduction

    The flash pattern setting controls the flash pattern. There are several available combinations of flash patterns, see table.

    Double, Triple, Quad, Single (1Hz), and Steady burn are built-in flash patterns and no control system is needed.

    The preset setting of flash pattern depends on the version of the lamp, see Preset Settings .

    When in configuration mode, the current flash pattern setting is shown in the flash sequence, see table.

    Flash pattern

    Flash control

    Color 1

    Color 2

    Double

    Double

    Built-in

    Triple

    Triple

    Built-in

    Quad

    Quad

    Built-in

    Single (1Hz)

    Single (1Hz)

    Built-in

    Steady burn

    Steady burn

    External

    Setting the Flash Pattern

    WARNING

    Risk of eye damage. Do not look into the light beam at close range.

    1. If already in configuration mode, go to step 6.

    1. If the lamp is connected to the power supply, disconnect it.

    2. Connect the red (colour 1)/yellow (colour 2) wire to 10-30 V DC via a 5 A fuse.

      L56_2C_connections_mounting_red.svg
      L56_2C_connections_mounting_yellow.svg
    3. Connect the black wire to ground.

      Lamp_56_2c_connections_mounting_black.svg
    4. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec.

      L56-2C__1_6_sec.svg

      The lamp enters configuration mode and a flash sequence indicating the current settings starts.

      Note

      If this step is performed incorrectly, you must restart from step 2.

    1. The selected flash pattern is displayed.

    2. Temporarily connect the white wire to ground again to change to the next version of flash pattern. Each time the white wire is temporarily connected to ground the next version of flash pattern is selected.

      White_to_ground_alone.svg
    3. To change the sync mode setting, see Sync Mode. To reset to factory settings, see Factory Reset.

    4. Disconnect the power supply to save the selected settings and exit configuration mode.